Page|12 TelecareandTelehealthProductRange v11Apr11
AMBIENT TEMPERATURE MONITOR
The Ambient Temperature Monitor should be wall mounted in the hallway or living room away from any
draughts or heat sources. When used in conjunction with a PIR, this device can be used to assess whether a
client is potentially at risk from hypothermia e.g. if they are not using their central heating system at night or
during winter months. The unit will generate a warning signal should the temperature drop below 16
o
C and
will activate an alarm condition should the temperature fall below 10
o
C for 30 minutes.
Features include;
Solid state temperature sensing element
Lower alarm temperature: <10
o
C for 30 minutes
Upper temperature threshold: 16
o
C
6-12 months battery life (typical) – user replaceable 3.6V Lithium
Daily battery self test & low battery reporting
Dimensions: 84 x 84 x 36 mm (HxWxD)
Ambient Temperature Monitor No. ZXT442
Compatible with SayPhone21, Advent xt & Altec Response
ENVIRONMENTAL
SAFETY
GAS DETECTOR
Gas Detectors should be wall mounted above door height in the kitchen, living room or anywhere with a gas
appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of gas is
detected a local alarm will sound and an alarm call will be transmitted.
A gas shut-off valve can also be activated.
Features include;
Semiconductor sensing element
85 dB sounder, power & alarm LED indicators
Complete with 5m mains cable and 3 pin plug
7 Watts power consumption
3-5 years detector life (inc transmitter battery)
Daily battery self test & low battery reporting
Dimensions: 120 x 110 x 60 mm (HxWxD)
Complies with BS 7348
Gas Detector Part No. ZXT423
Compatible with Reach, SayPhone, Advent xt & Altec Response
ENVIRONMENTAL
SAFETY
CARBON MONOXIDE DETECTOR
Carbon Monoxide Detectors should be wall mounted above door height in rooms that contain a fuel burning
appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of
carbon monoxide is detected a local alarm will sound and an alarm call will be transmitted.
Features include;
Electrochemical Cell sensor
85 dB sounder, power, fault & alarm LED indicators
Test/Hush button
Monthly self test & fault warning feature
3-5 years detector life (inc battery)
Daily battery self test & low battery reporting
Dimensions: 145 x 80 x 50 mm (HxWxD)
Complies with BS EN 50291: 2001
Carbon Monoxide Detector Part No. ZXT422